Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
Related Experiment Video
Updated: Jan 30, 2026

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Francisco Morales-Acuna1, Brycen Ratcliffe2, Caleb Harrison2
1Department of Rehabilitation Sciences, College of Health Sciences, The University of Texas at El Paso, 1851 Wiggins Way, El Paso, TX, 79968, USA. fmoralesac@miners.utep.edu.
Purpose:
Non-invasive central blood pressure assessed during exercise may provide better cardiovascular prognostic than measurements taken at rest. Radial tonometry is the only technique validated to perform this type of assessment; however, it relies on the experience of the tester. Cuff-based devices have been developed to avoid operator dependency, although these systems have yet to be validated during exercise. The purpose of this study was to compare exercise-induced central blood pressure estimations between a cuff-based device and radial tonometry.
Methods:
Twenty young healthy subjects were recruited to perform a three-workload steady-state exercise test at blood lactate levels of < 2, 2-4, and > 4 mmol/L, respectively. Central systolic and diastolic blood pressure (cSBP and cDBP, respectively), central pulse pressure (cPP), and augmentation index (AIx) were assessed at rest and during each workload with a cuff-based device and radial tonometry. Statistical analysis included Bland-Altman analysis for agreement between techniques. Agreement was considered when 95% of the data set for each central blood pressure parameter was within 1.96 standard deviations from the mean difference. Significance was considered at α = 0.05.
Results:
Central blood pressure measurements with the cuff device were obtained only at rest and during low-intensity exercise. During low-intensity exercise, all measurements showed agreement between both devices (cSBP 95% CI [- 6.0 to 10.7], cDBP 95% CI [- 4.5 to 6.3], cPP 95% CI [- 4.7 to 8.3], and AIx (95% CI [- 20.1 to 22.2]).
Conclusion:
A cuff-based device can estimate central blood pressure at low-intensity exercise, without operator dependency, and showing agreement to radial tonometry.
More Related Videos
Related Concept Videos
Peripherally and Centrally Acting Muscle Relaxants: A Comparison
Centrally acting muscle relaxants can be further divided into spasmolytic and antispasmodic drugs. Spasmolytic...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...