Related Experiment Video
Updated: Jan 30, 2026

Evaluating the Effectiveness of Cancer Drug Sensitization In Vitro and In Vivo
Published on: February 6, 2015
Ultrasound-responsive nanobubbles for enhanced intravitreal drug migration: An ex vivo evaluation
Sachin S Thakur1, Ying-Shan Chen2, Zachary H Houston3
1The University of Queensland, School of Pharmacy, Pharmacy Australia Centre of Excellence, 20 Cornwall Street, Woolloongabba, Brisbane, QLD 4102, Australia; Buchanan Ocular Therapeutics Unit, Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
Abstract:
The intravitreal route faces many challenges in rapidly and effectively reaching posterior eye pathology, with administered therapeutics experiencing non-specific distribution around and premature clearance from ocular tissues. Nanobubbles and ultrasound may improve outcomes of intravitreally administered drugs by influencing the directionality of drug-containing particle migration. In this study, we assessed the impact of trans-scleral or corneal ultrasound application on the distribution of intravitreally-injected nanobubbles. Rhodamine-tagged gas entrapped nanobubble formulations were prepared and injected into ex vivo bovine and porcine eyes and subjected to ultrasound (1 MHz, 0-2.5 W/cm2, 50-100% duty, 60 s). Bovine eyes were partially dissected to visualize the vitreous humor and particle migration was evaluated via optical fluorescence spectroscopy. Directional migration in porcine eyes was evaluated using a snap freezing protocol complemented by quantification of regional fluorescence. The impact on nanobubble migration following pars-plana injection and sequential ultrasound cycle application from scleral or corneal-surface positions was also assessed. Administration of ultrasound significantly enhanced the directional migration of nanobubbles in both ex vivo models, with multiple corneal ultrasound cycles promoting greater migration of dye-filled nanobubbles to posterior regions of the vitreous. Moreover, particles moved in a directional manner away from the ultrasound wave source demonstrating an ability to effectively control the rate and path of nanobubble migration. These findings establish an encouraging new and safe modality enabling rapid distribution of intravitreally-injected therapeutics where expeditious therapeutic intervention is warranted.
More Related Videos
09:53The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
Published on: February 9, 2021
07:29Deep Vascular Imaging in the Eye with Flow-Enhanced Ultrasound
Published on: October 4, 2021
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Factors Affecting Drug Response: Overview
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...