Related Experiment Video
Updated: Jan 30, 2026

Lower-Limb Biomechanical Characteristics Associated with Unplanned Gait Termination Under Different Walking Speeds
Published on: August 25, 2020
Two-minute walk tests demonstrate similar age-related gait differences as a six-minute walk test
Clayton W Swanson1, Zachary J Haigh2, Brett W Fling3
1Department of Health & Exercise Science, Colorado State University, CO, USA.
Background:
The six-minute walk test (6MWT) is used within clinical and research settings to assess gait performance across a variety of conditions and populations. Commonly, the test is used to identify specific aspects of gait that affect functional mobility. With the advancement of new technologies such as wireless inertial sensors, it has become possible to collect reliable, sensitive, and objective measures of gait. While the 6MWT has been accepted and used for many years, a more concise, while still objective gait analysis would likely benefit clinicians, researchers and patients.
Research Question:
Does a concise 2-minute walk test (2MWT) provide similar information regarding gait performance and gait differences as the 6MWT in healthy young (YA) and older adults (OA)?
Methods:
A total of thirty-one participants (sixteen young adults and fifteen older adults) conducted a continuous 6MWT at their self-selected pace. All participants wore six wireless inertial sensors which were placed on each foot, at the lumbar, sternum, and on each wrist. Once completed the 6MWT data was spliced into three, distinct two-minute segments. Spliced data was analyzed and compared between groups and segments.
Results:
Results demonstrate significant age-related differences in several gait metrics, primarily with older adults showing increased spatiotemporal variability. Additionally, no significant differences were observed between the three, two-minute segments and the continuous 6MWT, with the exception of total number of strides completed.
Significance:
These results demonstrate that the 2MWT may provide a preferable alternative to assessing gait performance by reducing confounds such as fatigue while maintaining sensitivity of measuring gait performance. These improvements may be particularly beneficial when studying populations of advanced age or with neurological disorder.
More Related Videos
06:28Author Spotlight: Developing Low-Tech Balance Assessment Methods for Broad-Spectrum Healthcare Applications
Published on: September 1, 2023
09:37Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults
Published on: May 12, 2016
Related Concept Videos
Aging
Cellular Clock Theory
The cellular clock theory posits that the human lifespan is closely tied to the finite capacity of cells to divide, a phenomenon governed by telomeres, which are protective caps at the ends of...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
The Effect of Aging on Tissues