Related Experiment Video
Updated: Jan 30, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Investigating the effect of dental implant materials with different densities on radiotherapy dose distribution using
Oya Akyol1, Bahar Dirican2, Turkay Toklu3
11 Department Radiation Oncology, Faculty of Medicine, Gazi University , Ankara , Turkey.
Objectives:
The aim of this study was to investigate the effect of dental implant materials with different physical densities on dose distribution for head and neck cancer radiotherapy planning.
Methods:
Titanium (Ti), Titanium alloy (Ti-6Al-4V), Zirconia (Y-TZP), Zirconium oxide (ZrO2), Alumina (Al2O3) and polyetheretherketone (PEEK) dental implant materials were used for determination of implant material effect on dose distribution. Dental implant effect was investigated by using pencil beam convolution (PBC) algorithm of Eclipse treatment planning systems (TPS) and Monte Carlo (MC) simulation technique. 6 MV photon beam of the Varian 2300 C/D linear accelerator was simulated by EGSnrc-based BEAMnrc MC code system.
Results:
Reasonable consistency was determined for percentage depth dose (PDD) curves between MC simulation and water phantom measurements at 6.4 MeV initial electron energy. The consistency between modelled linear accelerator PDD curve calculations and water-phantom PDD measurements were compatible within 1 % range. The dose increase in front of the dental implant calculated by MC simulation is in the range of 0.4-20.2%. We found by MC and PBC calculations that the differences in dose increase in front of the dental implant materials is in the range of 0.1-17.2% and is dependent on the physical density of the dental implant.
Conclusions:
Dose increase for Zirconia was noted to be maximum while PEEK implant dose increase was minimum among the whole dental implant materials studied. This study revealed that the Eclipse TPS PBC algorithm could not accurately estimate the backscatter radiation from dental implant materials.
Related Concept Videos
Distribution of Stresses in a Narrow Rectangular Beam
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Trial and Error and Algorithm
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...

