Accuracy of rapid test for diagnosis of hepatitis A with different infection rate settings and with predictive
Camilla R de Almeida Ribeiro1, Luciane A Amado2, Renata S Tourinho2
1Laboratory of Molecular Virology, Oswaldo Cruz Institute, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Aim:
We evaluated the accuracy of a commercial rapid immunochromatographic test (rapid test [RT]) for hepatitis A (HA) diagnosis and epidemiological studies.
Materials & Methods:
The accuracy of a RT was evaluated in laboratory and in field conditions. Predictive modeling estimated the test performance in a hypothetical population.
Results:
The RT showed sensitivities of 66-86%, and specificities of 21-100%, depending on the antibody isotype (IgM or IgG) analyzed and prevalence of infection.
Conclusion:
The RT is a good alternative for diagnostic in HA outbreaks. The predictive model indicates that it should not be used alone for HA diagnosis in low prevalence populations. These data can be used in the future to strengthen decision-making during the implementation of rapid diagnostic methods in health services.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Improving Translational Accuracy
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Predicting Molecular Geometry
Accuracy and Precision