Validation and Critical Evaluation of the Effective Arterial Elastance in Critically Ill Patients
Mathieu Jozwiak1,2, Sandrine Millasseau3, Christian Richard1,2
1AP-HP, Hôpitaux universitaires Paris-Sud, Hôpital de Bicêtre, service de réanimation médicale, Le Kremlin-Bicêtre, F-94270 France.
Objectives:
First, to validate bedside estimates of effective arterial elastance = end-systolic pressure/stroke volume in critically ill patients. Second, to document the added value of effective arterial elastance, which is increasingly used as an index of left ventricular afterload.
Design:
Prospective study.
Setting:
Medical ICU.
Patients:
Fifty hemodynamically stable and spontaneously breathing patients equipped with a femoral (n = 21) or radial (n = 29) catheter were entered in a "comparison" study. Thirty ventilated patients with invasive hemodynamic monitoring (PiCCO-2; Pulsion Medical Systems, Feldkirchen, Germany), in whom fluid administration was planned were entered in a " dynamic" study.
Interventions:
In the "dynamic" study, data were obtained before/after a 500 mL saline administration.
Measurements And Main Results:
According to the "cardiocentric" view, end-systolic pressure was considered the classic index of left ventricular afterload. End-systolic pressure was calculated as 0.9 × systolic arterial pressure at the carotid, femoral, and radial artery level. In the "comparison" study, carotid tonometry allowed the calculation of the reference effective arterial elastance value (1.73 ± 0.62 mm Hg/mL). The femoral estimate of effective arterial elastance was more accurate and precise than the radial estimate. In the "dynamic" study, fluid administration increased stroke volume and end-systolic pressure, whereas effective arterial elastance (femoral estimate) and systemic vascular resistance did not change. Effective arterial elastance was related to systemic vascular resistance at baseline (r = 0.89) and fluid-induced changes in effective arterial elastance and systemic vascular resistance were correlated (r = 0.88). In the 15 fluid responders (cardiac index increases ≥ 15%), fluid administration increased end-systolic pressure and decreased effective arterial elastance and systemic vascular resistance (each p < 0.05). In the 15 fluid nonresponders, end-systolic pressure increased (p < 0.05), whereas effective arterial elastance and systemic vascular resistance remained unchanged.
Conclusions:
In critically ill patients, effective arterial elastance may be reliably estimated at bedside (0.9 × systolic femoral pressure/stroke volume). We support the use of this validated estimate of effective arterial elastance when coupled with an index of left ventricular contractility for studying the ventricular-arterial coupling. Conversely, effective arterial elastance should not be used in isolation as an index of left ventricular afterload.
More Related Videos
Related Concept Videos
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Critical Thinking I
Critical Thinking II
Critical Thinking
Colleges and universities are...
Criticisms of the Evolutionary Perspective
Evolutionary psychology provides one explanation for these findings, suggesting...