Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Effects of flow pattern, device and formulation on particle size distribution of nebulized aerosol
Junhua Hu1, Rui Zhang1, Huimin Beng2
1Institute of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, Guangdong, China.
Abstract:
The evaluation of particle size recommended in the pharmacopeias requires a constant flow rate, and the method for pediatric inhaled drugs is the same as for adult drugs. In this study, the aerosol concentration and particle size distribution (PSD) were measured under a realistic breathing pattern and constant flow. Two types of nebulizer (i.e., breath-enhanced nebulizer and vibrating-mesh nebulizer) and two formulations (i.e., budesonide suspension and albuterol solution) were chosen for comparison. The aerosol concentration under the realistic pattern was not constant, which was different from the result at constant flow. The changing trend of aerosol concentration varied with the operation process of each device. The aerosol concentration profile was similar between budesonide suspension and albuterol solution. As to the PSD, as inspiratory flow increased, the X50 (50% undersize) increased with all nebulizers but Omron microAir NE-U22 nebulizer. There was good agreement between X50 obtained under the realistic inhalation patterns and their equivalent average flow rates by Bland-Altman analysis, although the X50 obtained under the realistic inhalation pattern was greater than value at constant flow. The agreement of the two breath-enhanced jet nebulizers was better than that of the vibrating-mesh nebulizers. The X50 of budesonide was not equal to that of albuterol when using the same nebulizer. Interestingly, a significant difference was observed in the X50 and Span when comparing the results of PSD under adult and child breathing patterns. Furthermore, all vibrating-mesh nebulizers produced aerosol droplets having larger mean diameter and narrower size distribution than those of the air-jet nebulizers. We conclude that it will be more conducive to the evaluation of particle size to use a laser diffractometer under a realistic pattern and make up for the shortcomings of cascade impactors. The effects of flow pattern, nebulizer and formulation should be taken into account in the evaluation of the qualities of nebulizer products in pharmaceutical practice.
More Related Videos
07:47Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
08:33Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Pore Size Distribution
Adequate...
Basic Postulates of Kinetic Molecular Theory: Particle Size, Energy, and Collision
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Biological Effects of Radiation