Related Experiment Video
Updated: Jan 30, 2026

Deep Neural Networks for Image-Based Dietary Assessment
Published on: March 13, 2021
Parallel imaging in time-of-flight magnetic resonance angiography using deep multistream convolutional neural
Yohan Jun1, Taejoon Eo1, Hyungseob Shin1
1School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea.
Purpose:
To develop and evaluate a method of parallel imaging time-of-flight (TOF) MRA using deep multistream convolutional neural networks (CNNs).
Methods:
A deep parallel imaging network ("DPI-net") was developed to reconstruct 3D multichannel MRA from undersampled data. It comprises 2 deep-learning networks: a network of multistream CNNs for extracting feature maps of multichannel images and a network of reconstruction CNNs for reconstructing images from the multistream network output feature maps. The images were evaluated using normalized root mean square error (NRMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) values, and the visibility of blood vessels was assessed by measuring the vessel sharpness of middle and posterior cerebral arteries on axial maximum intensity projection (MIP) images. Vessel sharpness was compared using paired t tests, between DPI-net, 2 conventional parallel imaging methods (SAKE and ESPIRiT), and a deep-learning method (U-net).
Results:
DPI-net showed superior performance in reconstructing vessel signals in both axial slices and MIP images for all reduction factors. This was supported by the quantitative metrics, with DPI-net showing the lowest NRMSE, the highest PSNR and SSIM (except R = 3.8 on sagittal MIP images, and R = 5.7 on axial slices and sagittal MIP images), and significantly higher vessel sharpness values than the other methods.
Conclusion:
DPI-net was effective in reconstructing 3D TOF MRA from highly undersampled multichannel MR data, achieving superior performance, both quantitatively and qualitatively, over conventional parallel imaging and other deep-learning methods.
Related Concept Videos
Magnetic Resonance Imaging
Parallel Resonance
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Force Between Two Parallel Currents
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and the vector product of the length vector along the current element and the field due to the first conductor. According to the...
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Atomic Nuclei: Magnetic Resonance

