Related Experiment Video
Updated: Jan 30, 2026

Automated Measurement of Microcirculatory Blood Flow Velocity in Pulmonary Metastases of Rats
Published on: November 30, 2014
A novel parameter for pulmonary blood flow during palliative procedures: velocity time integral of the pulmonary
Shuichi Shiraishi1, Keiko Bamba2, Ai Sugimoto1
1Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
Objectives:
The main goal of palliative procedures for congenital heart defects is adequate pulmonary blood flow (PBF), but precise intraoperative PBF evaluation is sometimes difficult. The purpose of this preliminary study was to investigate the usefulness of velocity time integral of the pulmonary vein (PV-VTI) measured by transoesophageal echocardiography (TOE) at the time of palliative procedure as a parameter for PBF.
Methods:
Case histories of 63 patients who underwent palliative procedures (bilateral pulmonary artery banding in 18 patients, main pulmonary artery banding in 22 patients and systemic-to-pulmonary artery shunt in 23 patients) and whose intraoperative PV-VTI was measured by TOE from 2011 to 2017 at our centre were retrospectively reviewed. Low-body-weight infants, cases in which cardiopulmonary bypass was used and cases that were anatomically difficult to measure were excluded.
Results:
PV-VTIs measured at 4 orifices of the pulmonary veins were all significantly decreased in both the bilateral pulmonary artery banding and main pulmonary artery banding groups and increased in the systemic-to-pulmonary artery shunt group immediately after the procedure. There were significant correlations between the velocity time integrals of both right and left pulmonary veins and arterial oxygen saturation (r = 0.564 and 0.703). Nine patients (6 bilateral pulmonary artery banding and 3 systemic-to-pulmonary artery shunt) required unplanned early reoperation due to inadequate PBF; their PV-VTIs were significantly different from those of patients not requiring reoperation. No major complications related to TOE occurred postoperatively.
Conclusions:
The PV-VTI measured by TOE during palliative procedures reflected the change of PBF and could help identify patients at higher risk of early reoperation due to inadequate PBF. This parameter may be a useful additional tool for evaluating intraoperative PBF.
More Related Videos
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
06:59Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Related Concept Videos
Applications of Integration to Find Blood Flow
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...
Other Pulmonary Disorders
Overview of Pulmonary Circulation
The process begins with the right ventricle of the heart pumping deoxygenated blood into the pulmonary trunk. This large vessel extends about 5 centimeters before splitting into the left and right pulmonary arteries. These arteries...