Annihilation gamma imaging for carbon ion beam range monitoring using Si/CdTe Compton camera
Raj Kumar Parajuli1, Makoto Sakai1,2, Wataru Kada3
1Gunma University Heavy Ion Medical Center, Gunma University, 3-39-22 Showa-machi, Maebashi, Gunma, Japan.
Abstract:
In this study, we performed on-beam monitoring of 511 keV annihilation gamma emissions using a Compton camera. Beam monitoring experiments were conducted using carbon ion beams of 290 MeV/u irradiated on a polymethyl methacrylate (PMMA) phantom. The intensity of the beams was 3 × 109 particles per pulse, with 20 pulses per minute. A Compton camera based on a silicon/cadmium telluride (Si/CdTe) detector was used to monitor the annihilation gamma rays emitted from the phantom. We successfully reconstructed the energy events of 511 keV annihilation gamma rays and developed Compton images using a simple back-projection method. The distribution of the annihilation gamma ray generation traced the beam trajectory and the peak intensity position was a few millimeters shorter than the Bragg peak position. Moreover, the effect of the beam range shifter with 30, 60, and 90 mm water equivalent thickness (WET) was clearly visualized in the reconstructed Compton images. The experimentally measured values of the corresponding range shifts in the PMMA phantom (28.70 mm, 52.49 mm, and 76.77 mm, respectively) were consistent with the shifts of the Bragg peak position (25.50 mm, 51.30 mm and 76.70 mm, respectively) evaluated by Monte Carlo simulation. The results show that the Si/CdTe Compton camera has strong potential for on-beam monitoring of annihilation gamma rays in particle therapy in clinical situations.
Related Concept Videos
The Carbon Cycle
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Common Ion Effect
Carbon Skeletons
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: