Cerebral Blood Flow Measured by Phase-Contrast Magnetic Resonance Angiography in Preterm and Term Neonates
Nienke Wagenaar1,2, Lucas H Rijsman1, Astrid Nieuwets1
1Department of Neonatology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
Background:
Preterm infants show a decreased tortuosity in all proximal segments of the cerebral vasculature at term-equivalent age (TEA). Recently MRI techniques were developed to measure cerebral blood flow (CBF) based on phase-contrast images.
Objectives:
We hypothesized that arterial CBF corrected for brain size differs between full-term and preterm infants at TEA.
Methods:
344 infants without major brain abnormalities had a cranial MRI for clinical reasons including phase-contrast magnetic resonance angiography (PC-MRA) around TEA (mean 41.1 ± SD 1.2 weeks). This cohort consisted of 172 preterm infants (gestational age at birth 24.1-31.9 weeks) and 172 term-born infants (gestational age at birth 37.0-42.6 weeks). The total CBF in milliliters/minute was calculated by adding the blood flow of the carotid and basilar arteries, and compared to age at scan, body weight, and several parameters of estimated brain size.
Results:
After logarithmic transformation, total CBF was associated with body weight, estimated brain weight, head circumference, and 2D brain surface measurements at TEA. Total CBF was significantly (9-12%) higher in term compared to preterm infants after correction for 2D brain surface measurements, head circumference or postmenstrual age at MRI (p < 0.05).
Conclusions:
Total CBF as measured by PC-MRA was associated with body and (estimated) brain weight and 2D brain surface measurements and was higher in term compared to preterm born infants.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Magnetic Resonance Imaging
Blood Flow
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....