Related Experiment Video
Updated: Jan 30, 2026

A Doxorubicin-Induced Murine Model of Dilated Cardiomyopathy In Vivo
Published on: May 16, 2020
β-Lapachone protects against doxorubicin-induced nephrotoxicity via NAD+/AMPK/NF-kB in mice
Davoud Sanajou1, Saeed Nazari Soltan Ahmad1, Vahid Hosseini1,2
1Department of Biochemistry, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
Abstract:
β-Lapachone (B-LAP) is a natural naphtaquinone with established anti-oxidative stress and anti-cancer activities. We aimed to investigate B-LAP protective potential against doxorubicin (DOX)-induced nephrotoxicity in mice. The mice received an oral dose of B-LAP followed by a single intraperitoneal injection of 20 mg/kg DOX a day later. They were then treated for 4 days with 1.25 mg/kg, 2.5 mg/kg, and 5 mg/kg doses of B-LAP. Renal levels of NAD+/NADH ratios, p-AMPKα, p-NF-κB p65, inducible nitric oxide synthase (iNOS), tumor necrosis factor alpha (TNF-α), interleukin 6 (IL-6) along with renal expressions of TNF-α, IL-1β, and IL-6 were examined. Serum levels of kidney function markers as well as renal histopathology were also investigated. In addition to increasing the activities of p-AMPKα, B-LAP elevated NAD+/NADH ratios in the kidneys and decreased the renal levels of nuclear p-NF-κB and its correspondent downstream effectors TNF-α, IL-1β, IL-6, and iNOS in the kidneys. Also, B-LAP effectively ameliorated renal architectural changes and attenuated serum levels of urea, creatinine, and cystatin C. Collectively, these findings suggest the protective actions of B-LAP against DOX-induced nephrotoxicity in mice.
Related Concept Videos
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Protecting Self-Esteem
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Personal Protective Equipment

