Related Experiment Video
Updated: Jan 30, 2026

A Mouse Model of Fatigue Induced by Peripheral Irradiation
Published on: March 17, 2017
Measurement and Evaluation of Local Surface Temperature Induced by Irradiation of Nanoscaled or Microscaled Electron
Zhenhai Wang1, Lijiang Gui2, Danhong Han1
1Key Laboratory for the Physics & Chemistry of Nanodevices, and Department of Electronics, Peking University, Beijing, 100871, China.
Abstract:
Electron beams (e-beams) have been applied as detecting probes and clean energy sources in many applications. In this work, we investigated several approaches for measurement and estimation of the range and distribution of local temperatures on a subject surface under irradiation of nano-microscale e-beams. We showed that a high-intensity e-beam with current density of 105-6 A/cm2 could result in vaporization of solid Si and Au materials in seconds, with a local surface temperature higher than 3000 K. With a lower beam intensity to 103-4 A/cm2, e-beams could introduce local surface temperature in the range of 1000-2000 K shortly, causing local melting in metallic nanowires and Cr, Pt, and Pd thin films, and phase transition in metallic Mg-B films. We demonstrated that thin film thermocouples on a freestanding Si3N4 window were capable of detecting peaked local surface temperatures up to 2000 K and stable, and temperatures in a lower range with a high precision. We discussed the distribution of surface temperatures under e-beams, thermal dissipation of thick substrate, and a small converting ratio from the high kinetic energy of e-beam to the surface heat. The results may offer some clues for novel applications of e-beams.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Electronic Distance Measuring Instruments
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Electron Affinity

