Related Experiment Video
Updated: Jan 30, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Measuring the accuracy of propofol target-controlled infusion (TCI) before and after surgery with major blood loss
Thomas Mohler1, JoEllen Welter1, Martina Steurer2
1Institute of Anaesthesia and Intensive Care Medicine, Spital Thurgau, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland.
Abstract:
Target-controlled infusion (TCI) is based on pharmacokinetic models designed to achieve a desired drug level in the blood. TCI's predictive accuracy of plasma propofol levels at the end of surgery with major blood loss has not been well established. This prospective observational study included adult patients (BMI 20-35 kg/m2) undergoing surgery with expected blood loss ≥ 1500 mL. The study was conducted with the Schnider TCI propofol model (Alaris PK Infusion Pump, CareFusion, Switzerland). Propofol levels were assessed in steady-state at the end of anaesthesia induction (Tinitial) and before the end of surgery (Tfinal). Predicted propofol levels (CTCI) were compared to measured levels (Cblood). Twenty-one patients were included. The median estimated blood loss was 1600 mL (IQR 1000-2300), and the median fluid balance at Tfinal was + 3200 mL (IQR 2320-4715). Heart rate, mean arterial blood pressure, and blood lactate did not differ significantly between Tinitial and Tfinal. The median bispectral index (0-100) was 50 (IQR 42-54) and 49 (IQR 42-56) at the two respective time points. At Tinitial, median CTCI was 2.2 µmol/L (IQR 2-2.45) and Cblood was 2.0 µmol/L (bias 0.3 µmol/L, limits of agreement - 1.1 to 1.3, p = 0.33). CTCI and Cblood at Tfinal were 2.0 µmol/L (IQR 1.6-2.2) and 1 µmol/L (IQR 0.8-1.4), respectively (bias 0.6 µmol/L, limits of agreement - 0.89 to 1.4, p < 0.0001). Propofol TCI allows clinically unproblematic conduct of general anaesthesia. In cases of major blood loss, the probability of propofol TCI overestimating plasma levels increases.Trial registration German Clinical Trials Register (DRKS; DRKS00009312).
Related Concept Videos
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Measurement of Blood Pressure
Accuracy and Precision