Ti-Catalyst Biomimetic Sensor for the Detection of Nitroaromatic Pollutants
Alizée Lemaire1, Philippe Hapiot1, Florence Geneste1
1Univ Rennes, CNRS, ISCR (Institut des Sciences Chimiques de Rennes) - UMR 6226 , F-35000 Rennes , France.
Abstract:
An electrode modified by a Ti complex in Nafion was used in the electrochemical detection of nitroaromatic compounds (NACs). The catalyst reduced nitroaromatic groups by a six-electron process with a high apparent rate constant, k1, which was estimated to be at least 19 000 mol-1 L s-1 by simulation of the first step of the cathodic reduction of 4-nitrophenylacetic acid, which was used as model molecule. The modified electrode was prepared and optimized in terms of Nafion and catalyst concentrations. In the chosen analytical medium, the Ti-catalyst-containing electrode showed good stability in the presence of nitro species. A standard deviation around 15% was calculated on the analysis performed with 28 different modified electrodes, which could be expected for a drop-coating process. We show that the modified electrode detects several nitroaromatic compounds such as nitrophenols, mononitroaniline, and dinitrotoluene with detection limits ranging from 1 × 10-4 to 9 × 10-4 g L-1 (0.2 × 10-6 to 5.1 × 10-6 mol L-1). As an interesting feature, the sensor exhibits good selectivity toward NAC detection because titanocene does not catalyze the reduction of nitroaliphatic compounds.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...