HPLC-UV-MS Analysis: A Source for Severe Oxidation Artifacts

Fritz Schweikart1, Gustaf Hulthe2

  • 1Advanced Drug Delivery, Pharmaceutical Sciences, IMED Biotech Unit , AstraZeneca , Gothenburg 43183 , Sweden.

Analytical Chemistry
|January 24, 2019
PubMed
Summary

UV detectors in HPLC systems can cause unwanted artifacts in mass spectrometry (MS) analysis. Radicals formed by UV light interfere with low-concentration samples, leading to misleading results in pharmaceutical development.

Related Concept Videos

Nodal Analysis with Voltage Sources01:11

Nodal Analysis with Voltage Sources

Nodal analysis is a remarkably effective method used in electrical engineering to simplify the analysis of complex circuits, including those with dependent or independent voltage sources. Its strength lies in its systematic approach to breaking down circuits into manageable components, making it easier for engineers to understand and solve.
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
2.0K
Mesh Analysis with Current Sources01:10

Mesh Analysis with Current Sources

Mesh analysis becomes simpler when analyzing circuits with current sources, whether independent or dependent. The presence of current sources reduces the number of equations required for analysis. Two cases illustrate this:
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
2.0K
Oxidation Numbers03:14

Oxidation Numbers

In redox reactions, the transfer of electrons occurs between reacting species. Electron transfer is described by a hypothetical number called the oxidation number (or oxidation state). It represents the effective charge of an atom or element, which is assigned using a set of rules.
42.6K
Pyruvate Oxidation01:15

Pyruvate Oxidation

After glycolysis, the charged pyruvate molecules enter the mitochondria via active transport and undergo three enzymatic reactions. These reactions ensure that pyruvate can enter the next metabolic pathway so that energy stored in the pyruvate molecules can be harnessed by the cells.
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
168.8K
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

Oxidation–Reduction Reactions
75.6K
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
2.1K