HPLC-UV-MS Analysis: A Source for Severe Oxidation Artifacts
Fritz Schweikart1, Gustaf Hulthe2
1Advanced Drug Delivery, Pharmaceutical Sciences, IMED Biotech Unit , AstraZeneca , Gothenburg 43183 , Sweden.
UV detectors in HPLC systems can cause unwanted artifacts in mass spectrometry (MS) analysis. Radicals formed by UV light interfere with low-concentration samples, leading to misleading results in pharmaceutical development.
Area of Science:
- Analytical Chemistry
- Pharmaceutical Analysis
- Chromatography
Background:
- High-Performance Liquid Chromatography (HPLC) coupled with UV and Mass Spectrometry (MS) is standard for purity assessments.
- Advancements in instrument sensitivity necessitate lower sample concentrations.
- Modern UV detectors exhibit higher light flux compared to previous generations.
Purpose of the Study:
- To investigate the impact of UV detector-induced degradation on MS signal integrity.
- To identify and illustrate artifact generation in typical pharmaceutical development samples.
- To highlight the potential for misleading mass spectra due to UV photodegradation.
Main Methods:
- Utilized HPLC coupled to UV and MS detection.
- Analyzed pharmaceutical development samples with varying analyte concentrations.
- Observed and characterized artifact signals in MS spectra resulting from UV exposure within the detector.
Main Results:
- UV light in the detector generates sufficient radicals to interfere with low analyte levels.
- Artifact signals in MS spectra were observed and directly linked to UV degradation.
- Examples from pharmaceutical development demonstrate severely misleading mass spectra.
Conclusions:
- Photodegradation within UV detectors poses a significant challenge for accurate MS analysis.
- The high light flux in modern UV detectors exacerbates this issue, especially with sensitive MS instruments.
- Careful consideration of UV detector use is crucial to avoid artifactual data in purity assessments.
Related Concept Videos
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Oxidation Numbers
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
Oxidation-Reduction Reactions
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...