Philip M Hemken1, Lori J Sokoll2, Xiaoqing Yang1,3
11Diagnostics Discovery Research and Development, Abbott Diagnostics, Abbott Laboratories, 100 Abbott Park Road, D09GP, AP20/1, Abbott Park, IL 60064 USA.
Background:
The biomarkers alpha-fetoprotein (AFP) and protein induced by vitamin K absence/antagonist-II (PIVKA-II) may be useful for detecting early-stage hepatocellular carcinoma (HCC). We evaluated the performance of AFP and PIVKA-II levels, alone and in combination with clinical factors, for the early detection of HCC.
Methods:
In a case-control study, serum AFP and PIVKA-II were measured using the ARCHITECT immunoassay analyzer system in a cohort of 119 patients with HCC, 215 patients with non-malignant liver disease, and 34 healthy subjects. Five predictive models for detecting HCC were developed based on age, gender, AFP, and/or PIVKA-II levels; the best model was validated in an independent cohort of 416 patients with HCC and 412 control subjects with cirrhosis.
Results:
In both cohorts, AFP and PIVKA-II concentrations were higher in patients with HCC compared to healthy controls and patients with non-malignant liver disease. The model that combined AFP and PIVKA-II, age, and gender had the highest AUC of 0.95 (0.95, 95% CI 0.93-0.98), with a sensitivity of 93% and a specificity of 84% in the development cohort, and an AUC of 0.87 (95% CI 0.85-0.90), sensitivity of 74%, and specificity of 85% in the validation cohort. When limiting the validation cohort to only early-stage HCC, the AUC was 0.85 (95% CI 0.81-0.88), sensitivity was 70%, and specificity was 86%.
Conclusions:
Compared to each biomarker alone, the combination of AFP and PIVKA-II with age and gender improved the accuracy of detecting HCC and differentiating HCC from non-malignant liver disease.
Related Concept Videos
Reliability and Validity
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
In Vitro Drug Release Testing: Overview, Development and Validation