Related Experiment Video
Updated: Jan 30, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
A computed tomography analysis of three-dimensional glenoid orientation modified by glenoid torsion
Noboru Matsumura1, Satoshi Oki1, Taku Suzuki1
1Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan.
Background:
The longitudinal axis of the glenoid is not always parallel to the scapular body, and glenoid torsion could affect the values of glenoid orientation. The purpose of this study was to evaluate 3-dimensional glenoid version and inclination modified by glenoid torsion and to clarify the differences between the values of conventional and of modified glenoid orientations.
Methods:
Computed tomography scans of 30 shoulders without shoulder pathology, 30 shoulders with primary osteoarthritis, and 30 shoulders with a massive rotator cuff tear or cuff tear arthropathy were retrospectively evaluated. After determining the glenoid axis and the scapular planes and calculating conventional glenoid version and inclination, modified glenoid version and inclination, and glenoid torsion, the values of conventional glenoid orientation and those of modified glenoid orientation were compared statistically.
Results:
All shoulders showed anterior torsion of the glenoid with an average of 16° ± 5°. The values of modified glenoid retroversion were significantly smaller than those of conventional glenoid retroversion in all groups (P < .033), and the values of the modified glenoid inferior inclination were significantly larger than those of conventional glenoid inferior inclination in all groups (P < .001).
Conclusions:
The present study showed that the glenoid twists with respect to the scapular body and that modification by glenoid torsion could affect the values of glenoid orientation. These results indicated that glenoid orientation with respect to the glenoid longitudinal axis will help surgeons determine proper placement of the glenoid component during shoulder arthroplasty.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Imaging Studies III: Computed Tomography

