Related Experiment Video
Updated: Jan 30, 2026

Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
Efficacy of lateral bone augmentation performed simultaneously with dental implant placement: A systematic review and
Daniel S Thoma1, Stefan P Bienz1, Elena Figuero2,3
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
Objectives:
To analyse the evidence regarding the efficacy of lateral bone augmentation procedures in terms of defect resolution in cases of horizontal ridge deficiencies after implant placement.
Materials And Methods:
Included studies met the following inclusion criteria: randomized controlled trials (RCTs) or controlled clinical trials (CCTs), re-entry procedure to assess defect resolution, minimum of 10 patients (5 per group). Meta-analyses were performed whenever possible, including subgroup analysis based on membranes and grafting materials.
Results:
Twenty-eight publications (20 short-term, 8 follow-up studies) were included. The most often used type of intervention was a xenogeneic particulated grafting material (XE) and a resorbable collagen membrane (CM). The mean defect height at baseline amounted to 5.1 mm (range 2.4-7.8) and decreased to a mean of 0.9 mm (range 0.2-2.2) at re-entry, and the mean defect resolution was 81.3% (range 56.4%-97.1%). Defect height reduction was not significantly different using CM+XE as control treatment compared to the combined data of the respective test groups [n = 11; weighted mean difference (WMD) = -0.006 mm; 95% CI, -0.61, 0.60; p = 0.985]. The absence of any lateral bone augmentation was less favourable than the conjunction of a membrane and a bone grafting material (n = 1; MD = -1.96 mm; 95% CI, -3.48, -0.44; p = 0.011). The lack of a grafting material was less favourable than the conjunction of grafting material and membrane (n = 1; MD = -2.44 mm; 95% CI, -4.53, -0.35; p = 0.022), and the addition of a membrane compared to a grafting material alone was more favourable (n = 3; WMD = 0.97 mm; 95% CI, 0.31, 1.64; p = 0.004).
Conclusions:
Lateral bone augmentation is a successful treatment modality. For optimal defect height reduction, a barrier membrane and a grafting material should be combined.
More Related Videos
Related Concept Videos
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Self-Efficacy
Random and Systematic Errors
Directing Effect of Substituents: meta-Directing Groups

