Related Experiment Video
Updated: Jan 30, 2026

Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Efficacy of Vein Visualization Devices for Peripheral Intravenous Catheter Placement in Preterm Infants: A Randomized
Seda Çağlar1, Funda Büyükyılmaz, İlkay Bakoğlu
1Pediatric Nursing Department (Dr Çağlar) and Fundamentals of Nursing Department (Dr Büyükyılmaz), Florence Nightingale Faculty of Nursing, Istanbul University-Cerrahpasa, Istanbul, Turkey; Neonatal Intensive Care Unit, Bakirköy Dr Sadi Konuk Education and Research Hospital, Health Sciences University, Istanbul, Turkey (Ms Bakoğlu and Dr Salihoğlu); and Department of Midwifery, Health Sciences Faculty, İstanbul University-Cerrahpasa, Istanbul, Turkey (Dr İnal).
Abstract:
The aim of this randomized controlled trial was to examine the efficacy of vein visualization devices and the routine method for insertion of peripheral intravenous catheters (PIVCs) in preterm infants. The study was conducted between June 2016 and April 2017 in the neonatal intensive care unit of Bakırköy Dr Sadi Konuk Education and Research Hospital. Participants (N = 90) were randomly assigned to the infrared group (n = 30), the transilluminator group (n = 30), or the control group (n = 30). Time to successful cannulation was significantly lower for the infrared group (8.70 ± 2.56 seconds) than for the transilluminator group (45.27 ± 30.83 seconds) and the control group (17.30 ± 8.40 seconds) (P ≤ .001). Success of the first attempt was significantly higher in the infrared and transilluminator groups than in the control group (P ≤ .05). Dwell time of the PIVC in place was significantly higher in the infrared group than in the transilluminator and control groups (P ≤ .05). Neonatal Infant Pain Scale scores were significantly higher in the transilluminator group (0.60 ± 0.855) than in the infrared (0.33 ± 0.182) and control groups (0.33 ± 0.182) while seeking an appropriate vein (P ≤ .001). The use of an infrared device provides efficacy in time to successful cannulation, success of the first attempt, length of the time the catheter is in place, and technique-related pain.
More Related Videos
03:53Author Spotlight: Regenerative Peripheral Nerve Interface (RPNI) Surgery in Postamputation Pain Management
Published on: March 15, 2024
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Trial and Error and Algorithm