Influence of Connector Diameter on Fracture Load of CAD/CAM-Processed Monolithic Lithium Disilicate Fixed Partial
Purpose:
To investigate the influence of connector diameter on the mechanical load to fracture in monolithic three-unit lithium disilicate fixed partial dentures (FPDs).
Materials And Methods:
A total of 24 FPDs were designed and manufactured using computer-aided design/computer-assisted manufacturing (CAD/CAM) with connector diameters of 16 mm2, 12 mm2, or 9 mm2 (Groups A, B, and C, respectively; n = 8 for each group). After thermal and mechanical aging, the FPDs were subjected to mechanical load-to-fracture assessment.
Results:
Fracture loads of Groups B (834 ± 105 N) and C (796 ± 41 N) were significantly lower compared to Group A (990 ± 65 N).
Conclusion:
Connector dimensions proved to be crucial for fracture resistance of monolithic lithium disilicate FPDs.
More Related Videos
06:022-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Partial Fractions
Fixed Action Patterns
Fixing Double-strand Breaks
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc