Related Experiment Video
Updated: Jan 30, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Contrast-enhanced ultrasound for evaluating the pathologic response of breast cancer to neoadjuvant chemotherapy: A
1Department of Ultrasound, Hebei General Hospital, Heping West Road, XinHua Qu, Shijiazhuang, China.
Objective:
Recent reports have suggested that contrast-enhanced ultrasound (CEUS) can be used to monitor the pathologic responses of breast cancer (BC) to neoadjuvant chemotherapy (NAC); however, the diagnostic performance of CEUS in BC has yet to be confirmed. Thus, we conducted a meta-analysis of related studies to explore the relationship between CEUS and pathologic responses of BC to NAC.
Materials And Methods:
We searched PubMed, Embase, Web of Science, ScienceDirect, and China National Knowledge Infrastructure databases for studies published until September 31, 2018. Study-specific odds ratios (ORs) and 95% confidence intervals (CIs) were calculated, and then ORs with 95% CIs were pooled to estimate the prognostic role of CEUS for the pathologic responses of BC to NAC.
Results:
Pooled meta-analysis of the 9 eligible studies that included 424 patients indicated the high performance of CEUS for monitoring pathologic responses to NAC (OR = 31.83, 95% CI: 16.69-60.67, P < .001), with no significant heterogeneity (I = 0.0%, P = .529). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 87% (95% CI: 0.81-0.92), 84% (95% CI: 0.74-0.91), 5.5 (95% CI: 3.3-9.2), 0.15 (95% CI: 0.10-0.23), and 36 (95% CI: 18-70), respectively. An area under the curve of 0.92 (95% CI: 0.89-0.94) suggests a high ability for prognostic detection. Although Begg's funnel plot (P = .057) indicated the presence of publication bias among the included studies, the trim-and-fill method verified the stability of the pooled outcomes. Sensitivity analysis suggested that the pooled OR was robust.
Conclusion:
Our results suggest that CEUS has a high diagnostic performance for the pathologic responses of BC to NAC. Further and better-designed studies should be performed to verify the clinical applications of CEUS for monitoring BC responses to NAC.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
05:44Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Cancer Survival Analysis
Directing Effect of Substituents: meta-Directing Groups
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Chemotherapy-Induced Nausea and Vomiting: Cannabinoids
Two synthetic agonists of THC,...