Related Experiment Video
Updated: Jan 30, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Reproducibility and validity of a novel invasive method of assessing peripheral microvascular vasomotor function
Scott Kinlay1,2,3, Mariah Bundy1, Melissa Chin1
1Department of Medicine, Cardiovascular Division, Veterans Affairs Boston Healthcare System, West Roxbury Campus, Boston, Massachusetts, United States of America.
Abstract:
In healthy arteries, blood flow is regulated by microvascular tone assessed by changes in blood flow volume and vascular resistance to endothelium-dependent and -independent vasodilators. We developed a novel method of using intravascular ultrasound (IVUS) and a Doppler flow wire to measure changes in blood flow volume and vascular resistance of the profunda arterial bed. We assessed the variability over 6 months in measuring microvascular endothelium-dependent dilation to acetylcholine and endothelium-independent dilation to adenosine in 20 subjects who were part of a larger study of Gulf War Illness without obstructive peripheral artery disease. Vasomotor function was assessed by Infusions of control (dextrose), acetylcholine (10-6M), adenosine (50μg), and nitroglycerin (25μg/ml). 400 IVUS and 240 flow velocity images were measured a mean 6 (SD = 2) months apart blind to measurement and infusion stage. The mean (SD) baseline profunda flow was 227 (172) ml/min and vascular resistance 4.6 x 104 (2.4 x 104) dynes-s/cm5. The intraclass correlation coefficients for 6-month variability for vascular function were excellent (range 0.827-0.995). Bland-Altman analyses showed mean differences of less than 2% for microvascular endothelium-dependent function (flow volume and resistance) and less than 1% for macrovascular endothelium-dependent function with acceptable limits of agreement. In 49 subjects assessing concurrent validity of the technique against atherosclerosis risk factors, we observed greater impairment in microvascular endothelium-dependent function per year of age (flow volume = -1.4% (p = 0.018), vascular resistance = 1.5% (p = 0.015)) and current smoking (flow volume = -36.7% (p = .006), vascular resistance = 50.0% (p<0.001)). This novel method of assessing microvascular vasomotor function had acceptable measurement reproducibility and validity.
Related Concept Videos
Reliability and Validity
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test