Evaluation of a resorbable self-locking ligation device for performing peripheral lung biopsies in a caprine
Adam M Nylund1, Chi-Ya Chen1, Odd V Höglund2
1College of Veterinary Medicine, Washington State University, Pullman, Washington.
Objective:
To compare airway leak pressures after sealing peripheral lung biopsy sites with a resorbable ligation device (LigaTie) or thoracoabdominal (TA) staples.
Study Design:
Ex vivo study.
Animals:
Four normal caprine cadavers.
Methods:
Twelve lung lobes were harvested from 4 goats immediately after euthanasia. Each lobe was inflated to 20 cm H2 O to test for leaks prior to biopsy. Pressure was then maintained at 10 cm H2 O. Biopsy samples were obtained 3 cm from the periphery with a resorbable ligation device or a TA stapler (n = 6 per group). After biopsy, inflation pressure was slowly increased to 40 cm H2 O while lungs were submerged in water. The pressure at which bubbles were first seen was recorded as the airway leak pressure. The length, width, volume, and weight were recorded for each biopsy sample.
Results:
Five of 6 LigaTie biopsy sites sustained the maximum pressure of 40 cm H2 O without leaking. One site leaked at 24 cm H2 O. The TA-stapled sites sustained airway pressure to median 25.5 cm H2 O (interquartile range, 23.5-26 cm H2 O), and none of them reached the maximum pressure (P = .015). There were no differences in biopsy length, volume, or weight between groups.
Conclusion:
Biopsy sites sealed with LigaTie withstood higher airway pressure without leaking compared with TA-stapled biopsy sites in normal cadaveric specimens.
Clinical Significance:
The LigaTie may be an alternative technique for sealing peripheral lung biopsy sites.
More Related Videos
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Lung Capacity
Self-Evaluation Maintenance Model
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...