Clinician accountability in a primary care clinic time-interval blood pressure measurements study: Practice
Johnny R Tice1, Leslie G Cole1, Stephen M Ungvary2
1The University of Alabama, Capstone College of Nursing, Tuscaloosa, AL 35401, United States of America.
Background:
Accurate blood pressure measurements (BPM) are important, as clinicians are tasked daily with using such measurements to make clinical diagnoses and patient care judgments. Research studies and controlled trials hold such measurements to a higher standard than everyday clinical practice.
Objective:
The aim of this study was to evaluate difference in BPM outcomes of individuals in a clinic setting when clinicians collect BPM as usual vs BPM after 5- (USPSTF recommendation) and 10- minute (study unique intervention) timed rest interval.
Methods:
A repeated-measures design was used to examine individual BPMs at the intervals of baseline, after a 5-minute rest interval post-baseline, and after a 10-minute rest interval post-baseline. Results Pairwise comparisons indicated that baseline SBP was the highest when compared to SBP measured at both 5- and 10-minutes post-baseline. SBP measured at 5-minutes was also significantly higher compared to SBP collected at 10-minutes post-baseline (ps < .05). For DBP, the repeated-measures ANOVA indicated that there was no significant difference across BPMs, F(2,198) = 1.25, p = .29.
Conclusions:
Results from this study revealed that implementing a 5-minute rest interval before BPMs are taken in a clinic setting produces a "clinically observable" reduction in the overall mean systolic BPs as seen at both 5- and 10-minute BPM intervals. It is important for all healthcare clinicians to recognize the importance of accurate BPM and the need to encourage better regulated BPM standard in everyday practice.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...