A new robust, deep eutectic-based floating organic droplets microextraction method for determination of lead in a
1Tokat Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey; Department of Chemistry, University of Turbat, Balochistan 92600, Pakistan.
Abstract:
In the present method, a novel and simple portable in situ deep eutectic-based floating organic droplets dispersive liquid-liquid microextraction method was developed for lead in real food and water samples by a portable microsampling syringe system directly couple with FAAS (DES-µSS). Choline chloride-decanoic acid (ChCl: Decanoic acid (1:1)) was used as a green hydrophobic deep eutectic-based floating organic droplets dispersive liquid-liquid microextraction of lead complex (Pb-2,9 dimethyl-4,7-diphenyl-1,10-phenanthroline) from real aqueous samples. The aqueous solution containing DES was rapidly 10 times sucked up/down by using a micro pipette tip syringe system to properly mix the extraction solvent in the aqueous medium. The whole solution was sucked into the micro pipette tip syringe system and placed in an ice bath for 5 min until decanoic base DES solidify into fine droplets. The solidify metal complex enriched (Pb-2,9 dimethyl-4,7-diphenyl-1,10-phenanthroline) was fine droplets was separated by simply press manually the plunger syringe system inside to expel the lower aqueous to the beaker. The different variables were screened out statistically by using multivariate optimization. Under these optimal conditions, good responses were obtained in the concentration ranges of 2.5-100 µg L-1. The relative standard deviation (RSD) and enhancement factor were found to be 4.2% and 150, respectively. The limit of detection (LOD) of the proposed method was found to be 0.086 µg L-1. The t-test was used to check the validity of the proposed method while using CRM samples. It was observed that calculated t value 0.50 less than the tcrit (2.91) at 95% confidence interval which indicating no significant difference between finding and certified values (p > 0.05). The relative % recovery is > 95%, indicated high validity and accuracy of the present method. The method was used to quantify the trace levels of lead in real water and food samples under optimized conditions.
Related Concept Videos
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Organic Compounds
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Buoyancy and Stability for Submerged and Floating Bodies