Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment
Saoirse O'Toole1, Cecilie Osnes2, David Bartlett3
1Department of Prosthodontics, King's College London Dental Institute, Floor 25, Tower Wing, Guy's Hospital, London SE19RT, UK.
Objectives:
Alignment procedures have yet to be standardised and may influence the measurement outcome. This investigation assessed the accuracy of commonly used alignment techniques and their impact on measurement metrics.
Methods:
Datasets of 10 natural molar teeth were created with a structured-light model-scanner (Rexcan DS2, Europac 3D, Crewe). A 300μm depth layer was then digitally removed from the occlusal surface creating a defect of known size. The datasets were duplicated, randomly repositioned and re-alignment attempted using a "best-fit" alignment, landmark-based alignment or reference alignment in Geomagic Control (3D Systems, Darmstadt, Germany). The re-alignment accuracy was mathematically assessed using the mean angular and translation differences between the original alignment and the re-aligned datasets. The effect of the re-alignment on conventional measurement metrics was calculated by analysing differences between the known defect size and defect size after re-alignment. Data were analysed in SPSS v24(ANOVA, post hoc Games Howell test, p<0.05).
Results:
The mean translation error (SD) was 139μm (42) using landmark alignment, 130μm (26) for best-fit and 22μm (9) for reference alignment (p<0.001). The mean angular error (SD) between the datasets was 2.52 (1.18) degrees for landmark alignment, 0.56 (0.38) degrees for best-fit alignment and 0.26 (0.12) degrees for reference alignment (p<0.001). Using a reference alignment statistically reduced the mean profilometric change, volume change and percentage of surface change errors (p<0.001).
Significance:
Reference alignment produced significantly lower alignment errors and truer measurements. Best-fit and landmark-based alignment algorithms significantly underestimated the size of the defect. Challenges remain in identifying reference surfaces in a robust, clinically relevant method.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Improving Translational Accuracy
Improving Translational Accuracy
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Leaky Scanning