Uterine factor in recurrent pregnancy loss

Jenna M Turocy1, Beth W Rackow1

  • 1Department of Obstetrics & Gynecology, Columbia University Medical Center, Fertility Center, 5 Columbus Circle, PH, New York, New York, USA.

Seminars in Perinatology
|January 27, 2019
PubMed
Summary

Uterine abnormalities, including congenital and acquired conditions, are linked to recurrent pregnancy loss. Surgical hysteroscopy can effectively manage abnormalities like uterine septum, adhesions, and submucosal myomas.

Related Concept Videos

Uterine Tubes01:16

Uterine Tubes

The uterine or fallopian tubes function as the conduit through which oocytes travel from the ovaries to the uterus. Each fallopian tube measures approximately 10 to 13 cm long and is anatomically divided into the infundibulum, ampulla, isthmus, and interstitial part (or intramural segment). The infundibulum is characterized by its funnel shape and features extensions called fimbriae which reach towards the peritoneal cavity. These fimbriae play a critical role during ovulation as they extend...
2.3K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
541
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
385
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.3K
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K