Related Experiment Video
Updated: Jan 30, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Unusual van Deemter plots of optical isomers on a chiral brush-type liquid chromatography column
Leonid D Asnin1, Anastasiia A Boteva1, Olga P Krasnykh1
1Perm National Research Polytechnic University, 29 Komsomolsky Al., Perm 614990, Russian Federation.
Abstract:
Unusual dynamic behavior of the enantiomers of 9-bromo-11b-(tert-butyl)-2,3,6,11b-tetrahydrooxazolo[3',2':1,5]pyrrolo[3,4-b]quinoline-5,11-dione (I) was observed on a Nautilus-R column packed with silica grafted with antibiotic ristocetin. It consisted in (i) antibatic behavior of the van Deemter plots of the enantiomers and (ii) high and strongly enantiomer dependent values of the A- and B-terms of the van Deemter equation. Although rare, such a pattern has been found earlier in chiral chromatography, with all reported cases limited to brush-type chiral stationary phases. Adsorption dynamics in this system was studied by means of the moment method and the peak parking technique; hydrodynamic properties of the column were explored by using unretained tracers. It was shown that the peculiar shape of the van Deemter curves for the enantiomers of I is conditioned by imperfect packing of the stationary phase, which result in high transcolumn eddy dispersion, and by slow adsorption/desorption kinetics. It was proven that the whole void volume of the column available to an eluent is not accessible to the studied analyte because it cannot penetrate the space between neighboring grafted ligands. Its mass transfer in pores is also affected by the fact that the stagnant layer of the binary water-acetonitrile mobile phase differs in composition from the bulk liquid due to preferential adsorption of water that influences the apparent molecular diffusivity of solutes. An effect of the structures of analyte and chiral selector on the adsorption kinetics is also briefly discussed.
More Related Videos
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Unusual Results
According to the range rule of thumb, any value above or below two standard deviations, 2σ from the mean, μ is considered unusual.
Maximum unusual value =...

