Neurosurgical Device Implantation for Neurooncologic Patients: What To Avoid?
Elly Chaskis1, Niloufar Sadeghi2, Olivier De Witte1
1Department of Neurosurgery, Erasme Hospital, Free University of Brussels, Brussels, Belgium.
Background:
Neurooncologic patients frequently require surgery, and neurosurgical devices are often implanted during neurosurgery. These devices could disturb oncologic follow-up by magnetic resonance imaging.
Methods:
The authors describe the use of neurosurgical devices, such as bone substitutes, ventriculoperitoneal shunts, and titanium skull fixations, in neurooncologic patients.
Results:
Acrylic cement cranioplasty, valve of ventriculoperitoneal shunt, and titanium skull fixations produced magnetic artifacts disturbing postoperative magnetic resonance imaging.
Conclusions:
The authors highlight the fact that all these neurosurgical devices implanted during surgery should be carefully evaluated to allow appropriate imaging follow-up for neurooncologic patients, which is a problem that remains underreported in the literature.
Related Concept Videos
Frustration and Conflict: Avoidance-Avoidance, Double-Approach Avoidance
Personality Disorders: Narcissistic and Avoidant
Characteristics of Narcissistic Personality Disorder
Narcissistic individuals exhibit an inflated sense of self-importance and an excessive need for admiration. They are often...
Avoidance Learning and Learned Helplessness
Avoidance learning occurs when an organism learns that a specific behavior can prevent an unpleasant outcome. For example, a student who receives a bad grade may start studying harder to avoid future poor grades. This behavior persists even when the negative outcome is no longer present. Avoidance learning is powerful because it maintains behavior in the absence of the...
Primary Motives: Sleep, Sex, and Pain Avoidance
Sleep is a fundamental physiological drive that fosters a state of restfulness crucial for several bodily functions. It facilitates body restoration, the process by which the body repairs, rejuvenates, and maintains itself during sleep, including memory...
Frustration and Conflict: Approach-Approach, Approach-Avoidance
One common type of conflict is the Approach–Approach Conflict. In this case, a person faces two desirable...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...