Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
A novel microfluidic resistive pulse sensor with multiple voltage input channels and a side sensing gate for particle
Tong Zhou1, Yongxin Song1, Yapeng Yuan1
1Department of Marine Engineering, Dalian Maritime University, Dalian, 116026, China.
Abstract:
Traditionally, a resistive pulse sensor (also known as Coulter counter) works by letting a particle pass through a small orifice in an electrolyte solution. The detection sensitivity mainly relies on the volume ratio of the particle to the orifice. This paper presents a novel resistive pulse sensor which has a sensing orifice located on the side wall of a microchannel. In this way, the sensor can detect and count particles (or cells) without requiring particles (or cells) passing through the sensing gate. An equation was derived to relate the magnitudes of the detected signals and the electrical resistances. Results show that the magnitudes of the detected signals can be increased by applying voltages from more than one voltage input channels simultaneously. Under the same conditions, the magnitudes of the detected signals become larger when the diameters of particles are larger. Higher detection sensitivity can be obtained simply by increasing either the magnitudes of the applied voltages or the number of the voltage input channels, or reducing the opening of the side sensing gate to a size that is even smaller than the diameter of the particle. Due to the high detection sensitivity, detection of 1 μm particles by a relatively large sensing gate of 5 × 10 × 10 μm (width × length × height) was successfully demonstrated with a signal to noise ratio (S/N) of approximately 3. This sensor was also applied to detect and count human red blood cells and lymphocyte cells. Results show that this method can clearly distinguish the cells with different sizes based on the pre-determined-thresholds. Because this sensor does not require cells to pass through the sensing gate, the channel clogging problem can be avoided. More importantly, the detection sensitivity can be tuned by applying different voltages without fabricating a smaller sensing gate.
More Related Videos
Related Concept Videos
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism....
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Mechanically-gated Ion Channels
G-Protein Gated Ion Channels
Sensory...