Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Unattended Versus Attended Blood Pressure Measurement
Massimo Salvetti1, Anna Paini1, Carlo Aggiusti1
1From the Department of Clinical and Experimental Sciences, University of Brescia, 2a Medicina ASST Spedali Civili di Brescia, Italy.
Abstract:
It has been suggested that measurement of unattended or automated oscillatory blood pressure (BP) values may provide advantages over conventional BP measurement. Some international guidelines now suggest automated oscillatory BP as the preferred approach for measuring BP. Data on the relationship between automated oscillatory BP and cardiovascular events are much less solid as compared to those obtained with the standard approach; preliminary data suggested that automated oscillatory BP might be more strictly correlated with organ damage. The aim of our study was to evaluate the relationship between attended or unattended BP and organ damage in 564 subjects undergoing an echocardiogram and carotid ultrasound at an European Society of Hypertension Excellence Center.Both unattended BP (patient alone in the room, an oscillometric device programmed to perform 3 BP measurements, at 1-minute intervals, after 5 minutes) and attended BP were measured with the same device, on the same day of the ultrasonographic examination, in random order. In 564 patients (age 61±15 years, 41% female 78% hypertensives) systolic unattended BP was lower as compared with attended BP (128.0±15.5 versus 134.5±19.9 mm Hg). Left ventricular mass index was similarly correlated with attended and unattended systolic BP ( r=0.205 and r=0.194, respectively). Carotid intima-media thickness was also significantly correlated with both attended and unattended systolic BP (mean max intima-media thickness: r=0.206 and r=0.194, respectively, P<0.0001). The differences between correlations were not statistically significant. Our results suggest that attended and unattended BP values are similarly related with hypertensive organ damage.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...