Related Experiment Video
Updated: Jan 30, 2026

Stress-induced Antibiotic Susceptibility Testing on a Chip
Published on: January 8, 2014
Evaluation of antibiotic susceptibility test results: how guilty a laboratory could be?
Mohamed S M Nassar1, Walaa A Hazzah1, Wafaa M K Bakr1
1Department of Microbiology, High Institute of Public Health, Alexandria University, Alexandria, Egypt.
Background:
The selection of an appropriate antimicrobial is a challenging task for clinicians. The Kirby-Bauer disk diffusion method is one of the most widely practiced antimicrobial susceptibility tests (AST). It is affected by many factors among which are the media used. Mueller-Hinton agar (MHA) is the standard medium recommended in guidelines. However, these guidelines are not strictly adhered to in some developing countries.
Objectives:
Validation of AST results on nutrient agar (NA) medium used as a substitute for MHA by some microbiology laboratories in Alexandria, Egypt.
Methods:
A total of 149 clinical bacterial isolates and 3 reference strains: Staphylococcus aureus (S. aureus) ATCC® 25923, Escherichia coli (E. coli) ATCC®25922, and Pseudomonas aeruginosa (P. aeruginosa) ATCC®27853 were comparatively challenged to antibiotics employing MHA and NA.
Results:
All antibiotics-reference bacterial strain challenges on NA compared to MHA were unacceptable (> 3 out of limit zones in 30 consecutive days). Considering clinical isolates, the frequency of very major, major, and minor errors on NA was highest in the case of P. aeruginosa (8.98%, 4.08%, and 14.7% respectively) followed by S. aureus (7.6%, 6%, and 8.8% respectively). On the other hand, the least frequency of errors was in the case of Enterobacteriaceae (0%, 0.4%, and 3.2% respectively).
Conclusions And Recommendations:
Using NA in AST resulted in multiple errors and the high discrepancy in results compared to MHA making it unreliable for susceptibility testing. MHA should not be replaced by NA in AST. Following guidelines and QC measures for AST must be neither bypassed nor underestimated.
More Related Videos
11:25Preparation of a Blood Culture Pellet for Rapid Bacterial Identification and Antibiotic Susceptibility Testing
Published on: October 15, 2014
08:04Quantitative Examination of Antibiotic Susceptibility of Neisseria gonorrhoeae Aggregates Using ATP-utilization Commercial Assays and Live/Dead Staining
Published on: February 8, 2019
Related Concept Videos
Antibiotic Selection
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Susceptibility, Permittivity and Dielectric Constant
Development of Antibiotic Resistance
Serum Laboratory Studies, Stool Test, Breath Test
Self-Evaluation: Self-Enhancement and Self-Verification