Supraciliary microstent implantation for open-angle glaucoma: multicentre 3-year outcomes

Swaantje Grisanti1, Salvatore Grisanti1, Julian Garcia-Feijoo2

  • 1Klinik fuer Augenheilkunde, Universitaetsklinikum Schleswig-Holstein, Luebeck, Germany.

BMJ Open Ophthalmology
|January 29, 2019
PubMed
Summary

The CyPass supraciliary microstent effectively lowered intraocular pressure (IOP) in open-angle glaucoma (OAG) patients for up to 3 years, with a safety profile comparable to other minimally invasive glaucoma surgeries.

Related Concept Videos

Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
993
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.2K
Glaucoma: Overview01:25

Glaucoma: Overview

Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.4K
Contact Angle01:13

Contact Angle

When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
19.2K
Predicting Reaction Outcomes02:24

Predicting Reaction Outcomes

Kinetics describes the rate and path by which a reaction occurs. In contrast, thermodynamics deals with state functions and describes the properties, behavior, and components of a system. It is not concerned with the path taken by the process and cannot address the rate at which a reaction occurs. Although it does provide information about what can happen during a reaction process, it does not describe the detailed steps of what appears on an atomic or a molecular level. On the other hand,...
10.8K
Outcomes of Glycolysis01:13

Outcomes of Glycolysis

Nearly all the energy used by cells comes from the bonds that make up complex organic compounds. These organic compounds are broken down into simpler molecules, such as glucose. As a result, cells extract energy from glucose over many chemical reactions—a process called cellular respiration.
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
107.1K