Related Experiment Video
Updated: Jan 30, 2026

Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
Published on: September 18, 2020
Activity Monitor Placed at the Nonparetic Ankle Is Accurate in Measuring Step Counts During Community Walking in
Noémie C Duclos1,2, Larissa T Aguiar1,2,3, Rachid Aissaoui4
1School of Rehabilitation, Faculty of Medicine, Université de Montréal, Montreal, Canada.
Background:
Different environmental factors may affect the accuracy of step-count activity monitors (AM). However, the validation conditions for AM accuracy largely differ from ecological environments.
Objectives:
To assess and compare the accuracy of AM in counting steps among poststroke individuals: during different locomotor tasks, with AM placed at the nonparetic ankle or hip, and when walking in a laboratory or inside a mall.
Design:
Validation study.
Settings:
Laboratory and community settings.
Participants:
Twenty persons with chronic hemiparesis, independent walkers.
Methods:
First session: participants performed level walking (6-minute walk test [6MWT]), ramps, and stairs in the laboratory with AM placed at the nonparetic ankle and hip. Second session: participants walked a mall circuit, including the three tasks, with AM placed at the nonparetic ankle. The sessions were video recorded.
Main Outcome Measurements:
Absolute difference between the steps counted by AM and the steps viewed on the video recordings (errors, %); occurrence of errors greater than 10%.
Results:
Median errors were similar for the 6MWT (0.86 [0.22, 7.70]%), ramps (2.17 [0.89, 9.61]%), and stairs (8.33 [2.65, 19.22]%) with AM at the ankle. Step-count error was lower when AM was placed at the ankle (8.33 [2.65, 19.22]%) than at the hip (9.26 [3.25, 42.63]%, P = .03). The greatest errors were observed among the slowest participants (≤0.4 m/s) on ramps and stairs, whereas some faster participants (>1 m/s) experienced the greatest error during the 6MWT. Median error was slightly increased in the mall circuit (2.67 [0.61, 12.54]%) compared with the 6MWT (0.50 [0.24, 6.79]%, P = .04), with more participants showing errors >10% during the circuit (7 vs 2, P = .05).
Conclusions:
Step counts are accurately measured with AM placed at the nonparetic ankle in laboratory and community settings. Accuracy can be altered by stairs and ramps among the slowest walkers and by prolonged walking tasks among faster walkers.
Level Of Evidence:
III.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
05:53Measuring Frailty in HIV-infected Individuals. Identification of Frail Patients is the First Step to Amelioration and Reversal of Frailty
Published on: July 24, 2013
Related Concept Videos
What are Populations and Communities?
Reliability and Validity
Self-Presentation: Self-Monitoring and Self-Handicapping
Ankle Joint
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Impact of Individuals on Individuals