Related Experiment Video
Updated: Jan 30, 2026

Motor Dual-Tasks for Gait Analysis and Evaluation in Post-Stroke Patients
Published on: March 11, 2021
Dual-Propeller Cavopulmonary Pump for Assisting Patients with Hypoplastic Right Ventricle
Jakin N Jagani1, Alexandrina Untaroiu2, Amit D Kalaria3
1From the Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
Abstract:
Various congenital heart defects (CHDs) are characterized by the existence of a single functional ventricle, which perfuses both the systemic and pulmonary circulation. A three-stage palliation procedure, including the final Fontan completion, is often adopted by surgeons to treat patients with such CHDs. The completion Fontan involves the creation of a total cavopulmonary connection (TCPC), commonly accomplished with an extracardiac conduit. This TCPC results in nonphysiologic flow conditions that can lead to systemic venous hypertension, reduced cardiac output, and ultimately the need for heart transplantation. A modest pressure rise of 5-6 mm Hg could correct the abnormal flow dynamics in these patients. To achieve this, we propose a novel conceptual design of a dual-propeller pump inside a flared TCPC. The TCPC dual-propeller conjunction was examined for hydraulic performance, blood flow pattern, and potential for hemolysis inside the TCPC using computational fluid dynamics (CFD). The effect of axial distance between the two propellers on the blood flow interference and energy loss was studied to determine the optimal separation distance. Both the inferior vena cava (IVC) and superior vena cava (SVC) propellers provided a pressure rise of 1-20 mm Hg at flow rates ranging from 0.4 to 7 lpm while rotating at speeds of 6,000-12,000 rpm. Larger separation distance provided favorable performance in terms of flow interference, energy loss, and blood damage potential. The ability of a dual-propeller micropump to provide the required pressure rise would help to augment the cavopulmonary flow and mimic flows seen in normal biventricular circulation.
More Related Videos
07:42Dual-Task Stroop Paradigm for Detecting Cognitive Deficits in High-Functioning Stroke Patients
Published on: December 16, 2022
06:52Laboratory Scale Slow Cook-Off Testing of Rocket Propellants: The Combustion Rate Analysis of a Slowly Heated Propellant CRASH-P Test
Published on: February 6, 2021
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Anatomy of the Brain: Ventricles
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...