Quality of CT Imaging of Periocular Metallic Foreign Bodies Using Artifact Reduction Software
Keirnan L Willett1, Mike Sheng2, Thomasine Gorry1
1Scheie Eye Institute, Department of Ophthalmology, University of Pennsylvania Perelman School of Medicine.
Purpose:
CT is the standard of care for assessment of ocular and orbital trauma; however, artifacts from metallic foreign bodies can limit the utility of CT. The authors hypothesize that implementation of metal artifact reduction techniques can improve image quality and diagnostic confidence for a diverse group of interpreters.
Methods:
A case series of ten subjects with retained periocular metallic foreign bodies imaged with CT were identified retrospectively from a large urban trauma center. Postacquisition images were processed with an iterative-based metal streak artifact reduction software. The severity of the metal streak artifact was assessed by clinicians including radiologists (4), ophthalmologists (4), and oculoplastic specialists (3) using a numeric scale to grade images on seven clinically relevant criteria. Each image was also analyzed to measure the size of the artifact and degree of streaking.
Results:
Overall confidence in diagnosis and severity of metallic streak was improved with metallic artifact reduction (p < 0.001, Wilcoxon signed-rank test). Similarly, confidence in assessing specific features-including extra-ocular muscle, optic nerve, globe rupture, orbital fracture and identification of foreign bodies-was improved after metallic artifact reduction (p < 0.001, Wilcoxon signed-rank test). The standard deviation of pixel intensity for a path surrounding the foreign body as well as the area of the streak artifact decreased in the metallic artifact reduction-processed images (p < 0.001, paired t test).
Conclusions:
Metal artifact reduction in CT has potential benefits in improving image quality and reader confidence for periocular trauma cases in real-world settings.
More Related Videos
08:31Candida albicans Biofilm Development on Medically-relevant Foreign Bodies in a Mouse Subcutaneous Model Followed by Bioluminescence Imaging
Published on: January 27, 2015
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Oxidation-Reduction Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Bonding in Metals