Ischemic Time in Free-Flap Surgery With Arteriovenous Bundle Interposition Graft: Comparison of Two Anastomosis
Yong-Ha Kim1, Jae-Won Kim, Tae-Gon Kim
1Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea.
Background:
During free-tissue transfer for scalp reconstruction, pedicle lengthening may be required when finding a recipient vessel is difficult because of defects from previous surgery. Arteriovenous (AV) bundle interposition grafting is a good option. This study compared 2 sequences of AV bundle interposition grafting when flap pedicle lengthening is needed.
Methods:
Two anastomosis methods were used. In the recipient lengthening type (R type), the flap was harvested and the AV bundle was harvested from a donor vessel for lengthening. In the flap lengthening type (F type), the flap was harvested first. Next, in contrast to that in the R type method, the authors performed anastomosis with a flap pedicle and bundle before the AV bundle was harvested.
Results:
The mean flap pedicle length was 8.75 cm (range, 5-11 cm). The AV bundle had a mean length of 9.25 cm (range, 6-13 cm), meaning that 13 cm of additional pedicle length can be added. The mean length of the extended vascular pedicle was 18 cm (range, 14-23 cm).
Conclusion:
This study compared the results of F type and R type AV bundle interposition grafting. The F type allowed easy monitoring of the anastomosis of the flap pedicle and ensured flap stability by reducing continuous ischemic time. Finally, this study confirmed the efficacy and safety of the AV bundle interposition graft in scalp reconstruction.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Cis-regulatory Sequences
Evolutionary Relationships through Genome Comparisons
Sequences
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...