Related Experiment Video
Updated: Jan 30, 2026

Head Implants for the Neuroimaging of Awake, Head-Fixed Rats
Published on: September 7, 2022
Implant vs abutment level connection in implant supported screw-retained fixed partial dentures with cobalt-chrome
Marco Toia1, Michele Stocchero1, Jonas P Becktor1
1Department of Oral and Maxillofacial Surgery and Oral Medicine, Malmö University, Malmö, Sweden.
Background:
Screw-retained fixed partial dentures (FPD) have shown a lower incidence of biologic complications and an easier retrievability compared with cemented FPD.
Purpose:
To compare the marginal bone loss at conical connection implant restored with a screw retained cobalt-chrome FPD in an implant-level (IL) or an abutment-level (AL) setup.
Materials And Methods:
Patients with at least two adjacent missing teeth were randomly allocated to be restored with IL or AL FPD. Periapical radiographs and clinical examination were taken at implant placement, prosthetic connection, 6 and 12 months to evaluate marginal bone loss (MBL), and soft tissue conditions. Complications were used to calculate prognostic indexes.
Results:
Fifty patients were treated with 50 FPD supported by 119 implants. The difference of MBL between the IL and AL groups was statistically significant (P = 0.003). At 1 year, MBL was 0.086 ± 0.313 mm and 0.005 ± 0.222 mm in the IL and AL groups, respectively. The presence of BoP increased with time in IL, whereas it decreased in AL group (P < 0.001). A minor complication was encounted in one FPD.
Conclusions:
A low grade of MBL was present after 1 year. IL showed greater amount of MBL and soft tissue inflammation indexes than AL. In FPD, AL may be a safer procedure than IL setup in order to preserve a healthy periimplant tissue.
More Related Videos
08:42The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice
Published on: July 26, 2024
08:11Surgical Training for the Implantation of Neocortical Microelectrode Arrays Using a Formaldehyde-fixed Human Cadaver Model
Published on: November 19, 2017
Related Concept Videos
Bone as Supporting Connective Tissue
Bone Matrix
Bone, or osseous tissue, is a connective tissue that has a large amount of two different types of matrix material. The organic matrix is similar to the matrix material found in other connective tissues, including some amount of collagen and elastic fibers. This gives strength and flexibility to the tissue. The inorganic matrix consists of mineral salts— mostly calcium salts—...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...