Accuracy of Two Ultrasound-Guided Coracohumeral Ligament Injection Approaches: A Cadaveric Study
Carl Majdalani1, Mathieu Boudier-Revéret1, John Pape2
1Department of Physical Medicine and Rehabilitation, Centre hospitalier de l'Université de Montréal, Montréal, Canada.
Background:
Glenohumeral idiopathic adhesive capsulitis is a common shoulder condition that hinders functionality. Addressing the pathology has been extensively researched. Ultrasound (US)-guided injections have shown their efficacy. However, no study has been conducted to compare anatomical accuracy between different approaches in targeting the coracohumeral ligament (CHL).
Objective:
To investigate whether US-guided injection of the CHL can be performed accurately using either the rotator interval (RI) or the coracoidal (CO) approach.
Methods:
An experimental cadaveric case series.
Setting:
Anatomy laboratory.
Specimens:
Both shoulders of 13 Thiel-embalmed cadavers.
Interventions:
Three physiatrists each injected a 0.1 mL bolus of colored dye in both shoulders of each cadaver using either the RI or the CO approach under US guidance. Each cadaver received a total of six injections (three injections per shoulder). The accuracy of the injection was determined following shoulder dissection by an anatomist.
Main Outcome Measure:
The accuracy of the US-guided injection of the CHL.
Results:
The RI approach yielded 36 accurate injections, giving it an accuracy of 100%. With the CO approach two injections were deemed inaccurate yielding an accuracy of 94%. There was no significant difference in accuracy between all operators.
Conclusions:
US-guided injection of the CHL can be performed accurately with both the RI and CO approaches. The RI approach was likely to be more accurate.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):