Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Direct Observation of Structure and Dynamics of Photogenerated Charge Carriers in Poly(3-hexylthiophene) Films by
Tomohisa Takaya1, Ippei Enokida2, Yukio Furukawa3
1Department of Chemistry, Faculty of Science, Gakushuin University, 1-5-1 Mejiro, Toshima-ku, Tokyo 171-8588, Japan. tomohisa.takaya@gakushuin.ac.jp.
Abstract:
The initial charge separation process of conjugated polymers is one of the key factors for understanding their conductivity. The structure of photogenerated transients in conjugated polymers can be observed by resonance Raman spectroscopy in the near-IR region because they exhibit characteristic low-energy transitions. Here, we investigate the structure and dynamics of photogenerated transients in a regioregular poly(3-hexylthiophene) (P3HT):[6,6]-phenyl-C61-butyric acid methyl ester (PCBM) blend film, as well as in a pristine P3HT film, using femtosecond time-resolved resonance inverse Raman spectroscopy in the near-IR region. The transient inverse Raman spectrum of the pristine P3HT film at 50 ps suggests coexistence of neutral and charged excitations, whereas that of the P3HT:PCBM blend film at 50 ps suggests formation of positive polarons with a different structure from those in an FeCl₃-doped P3HT film. Time-resolved near-IR inverse Raman spectra of the blend film clearly show the absence of charge separation between P3HT and PCBM within the instrument response time of our spectrometer, while they indicate two independent pathways of the polaron formation with time constants of 0.3 and 10 ps.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Lewis Structures and Formal Charges
Formal Charges
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3