Low-tube-voltage CT assessment of Adamkiewicz artery: Precise comparison between 100-kVp- and 120-kVp protocols
Yoshihiro Kubota1, Hajime Yokota1, Hiroki Mukai1
1Department of Radiology, Chiba University Hospital, 1-8-1, Inohana, Chuo-ku, Chiba City, Chiba, 260-8677, Japan.
Purpose:
Preoperative identification of Adamkiewicz artery (AKA) for preventing postoperative spinal cord ischemia is still challenging because of its small diameter. Low-tube-voltage technique might improve the delineation of AKA due to its higher contrast enhancement and contrast-to-noise ratio (CNR). Our purpose was to evaluate the usefulness of low-tube-voltage CTA in visualization of AKA compared with the conventional voltage protocol on the condition with the same imaging parameters aside from tube voltage.
Methods:
Eighty-three patients undergoing CTA for the evaluation of aorta were retrospectively included. All CTA was performed with 320-detector-row CT with the tube voltage of either 100-kVp (41 patients) or 120-kVp (42 patients). The CNR, CT value of aorta and objective image noise were assessed. Visualization of AKA was evaluated based on the continuity from aorta using the four-grade score by two independent reviewers. The estimated radiation dose (volumetric CT dose index) was also compared.
Results:
The 100-kVp group showed significantly higher CNR and CT value than 120-kVp protocol (P = 0.010 and < 0.001, respectively). The visual score was also significantly higher in 100-kVp group than in 120-kVp group (2.73 ± 0.98 and 2.02 ± 1.00, respectively; P = 0.002). There was no significant difference on objective image noise and radiation dose between the groups (P = 0.24 and 0.72, respectively).
Conclusion:
CTA with low-tube-voltage was significantly more sensitive for AKA visualization than conventional voltage protocol.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Voltage
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Uncertainty in Measurement: Accuracy and Precision
Voltage Dividers
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...