[Recent advances in hyphenation of nanoflow liquid phase separation with inductively coupled plasma mass
Fangfang Ding1,2, Jue Zhu1, Rui Guo1
1College of Chemistry & Chemical Engineering, Xiamen University, Xiamen 361005, China.
Abstract:
High-performance nanoflow liquid-phase separation techniques such as nanoflow liquid chromatography (nanoLC), capillary electrophoresis (CE), and microchip chromatography and electrophoresis (chip-ICP-MS) have been hyphenated with inductively coupled plasma mass spectrometry (ICP-MS) extensively. This hyphenation combines the excellent characteristics of the front-end separation technology, such as high selectivity, sensitivity, and speed, and low sample consumption, and the advantages of back-end ICP-MS, such as high resolution, wide dynamic range, and absolute quantification capability. Thus, such hyphenation is becoming an increasingly important analytical tool. Herein we systematically introduce the recent development of hyphenated nanoLC, CE, and chip-ICP-MS, review its application in chemical and biochemical analysis, and discuss potential future developments of hyphenating these technologies.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Mass Spectrometry: Overview