Doppler Color Scoring System in Women With an Incomplete Miscarriage: Interobserver and Intraobserver Reproducibility
Grace Ting Ting Leong1, Mathew Leonardi1, Chuan Lu2
1Acute Gynecology, Early Pregnancy & Advanced Endoscopic Surgery Unit, Sydney Medical School Nepean, University of Sydney Nepean Hospital, Penrith, Sydney, Australia.
Objectives:
Doppler Color Scoring (DCS) has been used to predict successful expectant management of incomplete miscarriage. The aim of this study was to assess inter- and intraobserver reproducibility of the DCS system in women with incomplete miscarriage noted on transvaginal sonography.
Methods:
This was a prospective reproducibility study involving offline analysis of 32 prerecorded video sets on transvaginal sonography in real time of women with incomplete miscarriage. Vascularization of retained products of conception was recorded using the DCS system adopted from the International Ovarian Tumor Analysis group. Five gynecologic sonologists of varying experience assigned a DCS classification to each video in the analysis. The same videos were reanalyzed, in a different order, at least 7 days later, to assess intraobserver agreement. Inter- and intraobserver correlations were performed to determine agreement. Interobserver agreement was also measured between each observer and the reference standard (G.C.). A Cohen's κ coefficient value less than 0 suggests poor agreement, 0.01 to 0.20 slight, 0.21 to 0.40 fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 and 0.99 almost perfect.
Results:
Interobserver agreement for all observers for DCS allocation ranged from 0.480 to 0.751. Overall interobserver agreement for 5 observers was substantial (κ, 0.626). Overall interobserver agreements for the 2 inexperienced and 3 experienced observers compared to G.C. were 0.521 and 0.618, respectively. Experienced observers achieved overall almost perfect intraobserver agreement, compared to substantial agreement for inexperienced sonologists.
Conclusions:
DCS interobserver reproducibility between all observers and GC ranged from moderate to substantial. DCS intraobserver reproducibility was substantial to almost perfect. The DCS system appears to be a reproducible tool in evaluating women with incomplete miscarriage.
Related Concept Videos
Incomplete Dominance
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Doppler Effect - I
Doppler Effect - II
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...