Evaluation of stray radiation to the operator for five hand-held dental X-ray devices
Richard Smith1, Richard Tremblay1, Graeme M Wardlaw1
11 Consumer and Clinical Radiation Protection Bureau , Health Canada , Canada.
Objectives:
Evaluate stray radiation to the operator, as represented by a plane within the significant zone of occupancy (SZO), produced by five models of hand-held intraoral dental X-ray devices (HIDXDs).
Methods:
The stray radiation for five models of HIDXDs was measured, using an anthropomorphic tissue-equivalent head phantom as a scattering object. An ionization chamber was used to measure the air kerma (μGy) at 63 positions in a 160 cm high by 60 cm wide plane that was 10 cm behind the X-ray device, identified as being within the SZO.
Results:
Based on the measured air kerma from stray radiation of five different HIDXDs, the estimated annual air kerma at all measured spatial positions was calculated. When calculated using a median air kerma of 0.8 mGy at the distal end of the cone, as typically required for digital image receptors, 1 the ranges for estimated annual air kerma in the SZO across the devices were 0.14-0.77 mGy for the median, 0.41-1.01 mGy for the mean, and 1.32-2.55 mGy for the maximum. Similarly, when calculated using a median air kerma of 1.6 mGy as typically required for D-speed film, 2 the ranges for estimated annual air kerma across the devices were 0.28-1.54 mGy for the median, 0.83-2.03 mGy for the mean, and 2.64-5.10 mGy for the maximum.
Conclusions:
From measured air kerma values of stray radiation in the SZO, estimated annual exposures to the operator for HIDXDs are expected to be greater than from conventional wall-mounted or portable devices activated from a protected area (at a distance or behind shielding). HIDXDs should therefore only be used when patient accessibility makes their use necessary and the use of a portable device on a stand or a wall-mounted device is not reasonably feasible. This approach would keep occupational radiation exposures of dental workers as low as reasonably achievable.
More Related Videos
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
09:43Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging
Published on: October 16, 2017
Related Concept Videos
Biological Effects of Radiation
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Hand hygiene
Hand washing...
Radiation: Applications
The average...
Absorption of Radiation
X-ray Imaging