Transcatheter aortic valve replacement in atypical valve anatomy using the Lotus valve : A Chinese single-center
1Department of Cardiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, 310009, Hangzhou, China.
Background:
In the West, the safety and efficacy of the Lotus valve have been demonstrated; however, data in the Chinese population are still lacking. Few studies have compared the clinical outcomes of transcatheter aortic valve replacement (TAVR) with the Lotus valve in patients with bicuspid or tricuspid aortic valve stenosis. Our aim was to assess TAVR outcomes with the Lotus aortic valve in a Chinese patient cohort.
Methods:
In total, 23 symptomatic, high-surgical risk patients with severe aortic valve stenosis were enrolled. Among them, nine patients (39%) had bicuspid aortic valves, and three patients had a large annulus dimension. The Lotus valve was successfully implanted in all patients. To facilitate accurate positioning, partial re-sheathing was attempted in ten patients (43.5%), while one patient had a full retrieval. One-year clinical follow-up was completed in all patients.
Results:
There were no deaths, strokes, or major adverse cardiac and cerebrovascular events in 22 of the 23 patients at 30 days; the all-cause mortality rate at 1 year was 4.4% (1 of 23 patients). The mean aortic valve gradient decreased from 51.5 ± 8.8 mm Hg at baseline to 13.4 ± 4.9 mm Hg (p < 0.001) and the valve area increased from 0.6 ± 0.2 cm2 to 1.5 ± 0.4 cm2 (p < 0.001) at 30 days. Paravalvular leakage was absent or mild (22%), and no patient had severe paravalvular leakage. Six patients (26.1%) required a postprocedural pacemaker. There was no difference regarding the procedural and the 1‑year outcomes between patients with bicuspid and tricuspid aortic valve stenosis.
Conclusion:
Our single-center experience demonstrated that the Lotus valve is feasible and effective for Chinese patients with aortic valve stenosis, including atypical cases with bicuspid aortic valves or large aortic annulus size.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Anatomy of the Heart
Anatomy of the Intestines
Small Intestines
The small intestine is an ~7 meter-long tube with an inner diameter of just 2.5 cm. Since most nutrients are absorbed here, the inner lining of the...