Related Experiment Video
Updated: Jan 30, 2026

Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
Published on: October 20, 2021
Three-Year Prospective Randomized Comparative Assessment of Anterior Maxillary Single Implants with Different
Purpose:
The goal of this investigation was to define time-dependent peri-implant tissue changes at implants with different abutment interface designs.
Materials And Methods:
Participants requiring replacement of single maxillary anterior and first premolar teeth were recruited and treated under an institutional review board (IRB)-approved protocol. Implants, titanium abutments, and provisional crowns were placed in healed ridges 5 months following preservation after tooth extraction with recombinant human bone morphogenetic protein-2 (rhBMP-2). Twelve weeks later, permanent crowns were placed on patient-specific abutments and evaluated at 6, 12, and 36 months following implant placement. Clinical and radiographic assessments of abutments and crowns, peri-implant mucosa, and marginal bone levels were recorded.
Results:
The 3-year assessment included 45 conical interface (CI), 34 flat-to-flat interface (FI), and 32 platform-switched interface (PS) implants in 111 participants. At 3 years, the mean marginal bone level (MBL) change at CI, FI, and PS implants was -0.12, -1.02, and -1.04 mm, respectively (P = .014). "Zero" MBL loss or gain was measured over the 3-year period at 72.1% CI, 3.0% FI, and 16.6% PS implants. There was a minor change (0.0 to 0.3 mm) in peri-implant mucosal zenith positions over time and between groups. Eighty percent of CI implants, 61% of FI implants, and 84% of PS implants were observed to have a clinically stable peri-implant mucosal zenith position with less than 0.5 mm of measured recession. Over the 36-month period, there were no significant changes in the location of mesial or distal papilla in any group.
Conclusion:
Significant differences in MBLs were observed at different implant interfaces. Conical implant interfaces, but not flat-to-flat or platform-switched implant interfaces, were associated with no MBL changes over 3 years. Peri-implant mucosal stability was generally observed. The relationship of marginal bone responses and peri-implant mucosal stability requires further evaluation.
More Related Videos
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
04:11Author Spotlight: Insights into an Efficient Murine Maxillary Orthodontic Model Protocol
Published on: October 27, 2023
Related Concept Videos
Protein-protein Interfaces
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...
Random and Systematic Errors
Random Sampling Method