Studying the effects of metallic components of PET-insert on PET and MRI performance due to gradient switching
Narjes Moghadam1, Romain Espagnet1, Jonathan Bouchard1
1Groupe de Recherche en Appareillage Médical de Sherbrooke (GRAMS), Interdisciplinary Institute for Technological Innovation (3IT), Department of Electrical and Computer Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada.
Abstract:
Inserting positron emission tomography (PET) detection modules inside an MRI bore imposes extra challenges owing to the behavior of metallic materials in a strong magnetic field. The metallic parts even when placed outside an MRI field of view may not only disturb MRI performance, but could also increase temperature and vibrations, leading to premature failure of PET electronics. To investigate the compatibility of detection modules inside 3 T, 7 T and 9.4 T MRI bore, a theoretical study of the metal induced artifacts originating from component materials of electronic circuit is presented. The LabPET II detection module and a modified version of it in which the connector was replaced by ball grid array (BGA) were studied. In addition, the effect of eddy current and the associated heat loss on the PET detection module have been examined using COMSOL Multiphysics® simulations for 10 kHz and 100 kHz gradient switching. Results show that displacement artifacts resulting from the presence of small amounts of ferromagnetic metal and the heating effects of metal due to gradient switching can be compensated by using the slightly modified LabPET II detection module. Thus, the LabPET II system would be MR-compatible with some minor adjustments to operate effectively inside an MRI bore without interfering with its performance.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....