Related Experiment Video
Updated: Jan 30, 2026

Surface Properties of Synthesized Nanoporous Carbon and Silica Matrices
Published on: March 27, 2019
[Surface morphology and surface properties of Ti and TiZr implant materials]
1Department of Oral Implantology, School of Stomatology, Lanzhou University, Lanzhou 730000, China.
Abstract:
Objective: To investigate the effects of hydrophilic treatment on the surface morphology and surface properties of pure titanium and titanium-zirconium alloy implants, and to provide reference for the studies of implant surface modification. Methods: The pure titanium group, the hydrophilic pure titanium group, the titanium zirconium alloy group and the hydrophilic titanium-zirconium alloy group were prepared by sandblasting and acid-etching or hydrophilic sandblasting and acid-etching, (11 specimens in each group). The surface morphology and surface properties of four types of titanium specimens were analyzed by surface contact angle meter, scanning electron microscope (SEM), optical profilometer, atomic force microscope (AFM) and Raman spectrometer. Results: The surface contact angles of hydrophilic pure titanium and hydrophilic titanium-zirconium alloy were 1.6°±0.3° and 1.5°±0.2°, and the surface contact angles of pure titanium and titanium-zirconium alloy were 101.4°±4.6° and 96.2°±3.0°, respectively. SEM showed that the nano-protrusions on the surface of pure titanium and titanium-zirconium alloys were less or even absent, while the nano-protrusions on the surface of hydrophilic pure titanium and hydrophilic titanium-zirconium alloys were relatively more; the nano-protrusions on the surface of hydrophilic pure titanium surface were small and dense relatively, but the nano-protrusions of the hydrophilic titanium-zirconium alloy had large diameters and were dispersed relatively. The optical profiler and AFM showed that the surface roughness of hydrophilic pure titanium and hydrophilic titanium-zirconium alloy was significantly higher than that of pure titanium and titanium-zirconium alloy (P<0.05). Raman spectroscopy showed that only the amorphous TiO(2) was present on the surface of the pure titanium group, while the rutile TiO(2) characteristic peak was observed in the other three groups, but the lateral inhomogeneity was observed. After Raman shift 610 cm(-1), the Raman spectra of four groups were similar. Conclusions: Hydrophilic sandblasting and acid-etching treatment can improve the surface hydrophilicity and surface roughness of pure titanium and titanium zirconium alloy, and improve the surface properties of pure titanium and titanium zirconium alloy implants.
Related Concept Videos
Surface Tension and Surface Energy
Consider a beaker filled with liquid. The bulk molecules in the liquid experience equal attractive forces on all sides with the surrounding molecules. However, the surface molecules experience a net attractive force downward due to the bulk molecules. The surface of the liquid behaves like a stretched membrane,...
Wood Surfacing
The equipment used in the surfacing process is a plane equipped with rotating blades. This tool efficiently smoothens the wood surface and can...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Cell-surface Signaling
Area of a Surface of Revolution
Equipotential Surfaces and Conductors

