Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With
Maria Cm Frade1, Ivanize Mm Dos Reis1, Renata P Basso-Vanelli2
1Spirometry and Respiratory Physiotherapy Laboratory, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
Background:
The importance of evaluating the functional capacity of patients with COPD is well known, and there is a wide range of tests described in the literature. The 6-min stationary walk test associated with virtual reality (STVR-6) was created in light of the current limitations of evaluation tests. It does not require a large physical space or sophisticated equipment, and it is not costly; furthermore, it can be performed by a single rater. The objective of this study was to evaluate intra- and inter-rater reproducibility and to verify the criterion validity of the STVR-6.
Methods:
50 subjects with COPD were evaluated over the course of 3 d. The execution order of the tests was randomized; the STVR-6 was performed over 2 d, and the 6-min walk test was performed in 1 d. The 6-min walk distance variables and number of steps in the STVR-6 were obtained with a gas analysis performed for both tests.
Results:
Relative reproducibility was found for intraclass correlation coefficient values (0.57-0.94, P < .001) between the number of steps and the highest value of oxygen consumption during the test (V̇O peak), intra- and inter-rater. In terms of absolute reproducibility, the standard error of measurement and minimum detectable difference values were verified. In the Bland-Altman analysis, the intra- and inter-rater mean difference values were 21 and 17 steps and 0.002 and 0.242 mL/min/kg, respectively. Pearson correlation values were 0.57-0.75 (P < .001) between the number of steps and V̇O peak.
Conclusions:
STVR-6 had excellent intra-rater reproducibility and excellent to good inter-rater reproducibility, but the high values of error measures demonstrated that there is a learning effect and a need to perform at least 2 tests. In addition, there was high to moderate correlation between the STVR-6 and the 6-min walk test. Therefore, the STVR-6 proved to be reproducible and valid for evaluating the functional capacity of subjects with COPD.
Related Concept Videos
Reliability and Validity
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
COPD: Management Using Bronchodilators and Corticosteroids
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Data Validation
Key parameters for method validation include: